Set of instruments for test protection against accidental touch

Set of instruments for test protection against accidental touch
 
The set of instruments is designed for testing electrical products to protect it from:
  • electrical shock under normal operating conditions;
  • solid objects penetration;
  • human access to dangerous parts of the products and
  • contact with foreign objects into inside of the products.

The set of instruments meets the requirements according to the standards:

  • HOST 14254-96 (MEK 529-89). Degrees of protection provided by protective shells (IP code).
  • HOST 25861-83 (ST REV 3743-82). Computing machines and data processing systems. Electrical and mechanical safety requirements and testing procedures.
  • DSTU IEC 60335-1:2004 Household and similar electrical appliances. Safety. Part 1. General requirements.
  • DSTU IEC 60065:2009 Audio, video and similar electrical appliances. Safety requirements.
The set of instruments consists of the following components:
  • set of testing instruments – 10 units;
  • signaling unit;
  • case for storing testing instruments and signaling unit.
Nomenclature and characteristics of the testing instruments
 
Testing instrument According to the standard Testing efforts, H
1. Tough test finger DSTU IES 60065 50-
2. Swivel test finger  HOST 14254
HOST 25861
DSTU IES 60065
DSTU IES 60335-1
-
10
-
20
3. Probe access HOST 14254 50
4. Test rod  2.5 mm diameter HOST 14254 3
5. Test rod  2.5 mm diameter 1,0 mm HOST 14254 1
Test pin DSTU IES 60065 10
Test nail DSTU IES 60335-1  10
Tough finger DSTU IES 60335-1 50
Test probe DSTU IES 60335-1
HOST 25861
-
Test rod DSTU IES 60335-1
HOST 25861
-
 
NOTE Deviation values of testing efforts within ± 10% for all instruments.
 
Technical characteristics of the signaling unit
 
Signaling unit power supply:
 
Voltage 220 V ± 22 V
Frequency 50 Hz ±1 Hz
The value of the output test voltage of DC generated by signaling unit 40 V ± 2 V
Power consumption, no more than  6 W
Overall dimensions of the case (set of instruments during storage), no more than:
  • length
  • width
  • height
460 mm
360 mm
165 mm
Weight of case with instruments and signaling unit, no more than 7,0 kg
 